Function | Range | Accuracy |
AC Current | 400/1000A | ±(3.0% rdg + 3 dgts) |
AC Voltage | 4/40/400V | ±(0.8% rdg + 5 dgts) |
700V | ±(1.0% rdg + 10 dgts) |
DC Current | 400/1000A | ±(3.0% rdg + 3 dgts) |
DC Voltage | 0.4/4/40/400V | ±(0.7% rdg + 1 dgt) |
1000V | ±(0.8% rdg + 3 dgts) |
Input Impedance | 10MΩ (AC and DC Voltage) |
Resistance | 400/4k/40k/400k/4MΩ | ±(1.2% rdg ± 1 dgt) |
40MΩ | ±(2.0% rdg + 3 dgts) |
Capacitance | 4n/40n/400n/4µ/40µF | ±(4.0% rdg + 10 dgts) |
Temperature | -40°C ~ 0°C | ±(1.0% rdg + 6 dgts) |
0°C ~ 400°C | ±(1.0% rdg + 3 dgts) |
400°C ~ 750°C | ±(1.0% rdg + 5 dgts) |
Frequency | 40/400/4k/40k/100kHz | ±(2.0% rdg + 1 dgt) |
Duty Cycle | 0.1% - 99.9% |
Diode | Read approximately forward voltage drop of the diode. |
Continuity | If continuity exists ≤ 30Ω, built in buzzer will sound. |
Display | 3¾ digits, 3999 counts |
Battery | 9V |
Size / Weight | H250 x W99 x D43mm / Approx. 480g |
Standard Accessories | Test Leads, “K” Type Bead Thermocouple, Hard Case, Battery, Manual |
Tidak ada komentar:
Posting Komentar