FEATURES
* Separate professional vibrationsensor.
* Vibration meter
Acceleration :
200 m/s^2, RMS, PEAK,
Max. Hold., g, ft/s^2.
Velocity :
200 mm/s, RMS, PEAK,
Max. Hold, cm/s, inch/s.
Displacement ( p-p ) :
2 mm, Max. Hold.
* Tachometer ( photo ) :
5 to 100,000 RPM.
Tachometer ( contact ) :
5 to 19,000 RPM.
Tachometer ( surface speed ) :
m/min., ft/min., inch/min.
* Laser photo tachometer.
* Data logger.
* Data hold, Record (max., min.).
* RS-232 computer interface.
* DC 1.5V ( UM-3, AA ) x 4 PCs.
* Patented.
1. FEATURES
Vibration function : Calibration Velocity 50 mm/s ( 160 Hz )* Applications for industrial vibration monitoring : point Acceleration 50 m/s^2 ( 160 Hz )
All industrial machinery vibrates. The level of vibration Displacement ( p-p ) 0.05 mm ( 160 Hz )
is a useful guide to machine condition. Poor balance, Memory Maximum & Minimum value.
misalignment & looseness of the structure will cause * Memory function are only available for
the vibration level increase, it is a sure sign that the RMS ( Acc., Vel. ) and Displacement (p-p).
maintenance is needed. Sampling time Approx. 1 second.
* Acceleration range : 200 m/s^2. Data logger Data logger function with flexible
* Velocity range : 200 mm/s. sampling time selection, can save max.
* Displacement ( p-p ) range : 2 mm. 1000-point data into the memory circuit.
* Metric and imperial display unit . Sampling Time Manual Push the data logger button
* RMS measurement for Acceleration and Velocity. of Data Logger once will save the data one
* Peak to peak measurement for Displacement. time.
* Peak function for Acceleration and Velocity. Auto 1, 2, 10, 30, 60, 600, 1800,
* Max. hold function for Acceleration ( peak ), 3600 seconds.
Velocity ( peak ) and Displacement ( peak to peak ). Sampling time Approx. 1 second.
* Frequency range 10 Hz - 1 kHz, sensitivity relative Power off Auto shut off, saves battery life,
meet ISO 2954. or manual off by push button.
* Zero function, executed by front buttons.
* Data logger function with flexible sampling time 2-2 Tachometer ( photo, contact ) function
selection, can save max. 1000-point data into the Range Photo Tachometer : 10 to 99,999 RPM
memory circuit. Contact Tachometer : 0.5 to 19,999 RPM
* Data hold button to freeze the desired reading. Surface Speed ( m/min. ) :
* Memory function to record maximum and minimum 0.05 to 1,999.9 m/min.
reading of RMS value ( Acc., Vel. ) or Displacement ( Surface Speed ( ft/min. ) :
p-p ). 0.2 to 6,560 ft/min.
* Auto shut off saves battery life. Accuracy ± ( 0.05 % + 1 digit ).
* Professional vibration meter supply with separate Resolution 0.1 RPM < 1,000 RPM
vibration sensor & magnetic base, full set. 1 RPM ≧1,000 RPM
0.01 m/min. < 100 m/min.
Tachometer ( photo, contact ) function : 0.1 m/min. ≧ 100 m/min.
* Laser light detecting source, long measuring range up 0.1 ft/min. < 1000 ft/min.
to 1.5 meters, it is useful in the RPM measurement 1 ft/min. ≧1,000 ft/min.
application where the machine would be a risk to the Time base Quartz crystal
operator or close access is difficult or not possible. Sampling Time Photo Tachometer - 1 sec. ( ≧60 RPM ).
* The best Tachometer in the world. 2 in 1, one Contact Tachometer - 1 sec. (≧6 RPM ).
instrument combine Photo Tachometer & Contact Photo 50 - 1,500 mm typically.
Tachometer. Tachometer * Spec. of detecting distance are that under
* Wide measuring range from 0.5 to 100,000 RPM, 0.1 detecting the size of reflecting tape is 10 mm square
RPM resolution for the measured value < 1000 RPM. distance & the measuring RPM value is 1,800 PPM.
* Microprocessor based circuit, crystal time base, high The max. & min. detecting distance may
precision with 0.05% accuracy. change under different environment,
* Memory with recall function, the last value, max., different reflecting tape or the measuring
value, min. value will be stored into the memory RPM beyond 1800 RPM.
automatically. Laser light * Less than 1 mW.
* Patent patented. source * Class 2 laser diode. Red. Wave length
* Photo Tach. is 645 nm approximately.
General function : Memory Last value, Max. value, Min. value.
* Super large LCD display.
* No contact infrared temperature measurement via 2-3 General function
optional IR temp. probe. Display 45 mm x 48 mm LCD size.
* RS 232 computer interface. Circuit Exclusive microcomputer circuit.
* Optional data acquisition software and data logger Data output RS 232 serial output.
software. Operating 0 to 50 ℃ ( 32 to 122 ℉ ).
* Microcomputer circuit, high performance. temperature
* Built-in low battery indicator. Operating Less than 80% RH.
* Heavy duty & compact housing case. humidity
* Complete set with the hard carrying case. Power supply 1.5 V battery x 4 PCs
UM-3, AA, R6
2-1 Vibration function Power Vibration Approx. 10.5 mA
Velocity 0.5 to 199.9 mm/s consumption Tachometer Approx. 21 mA
range 0.05 to 19.99 cm/s Weight Meter 397 g/0.87 LB
0.02 to 7.87 in/s Probe with 110 g/0.24 LB
Acceleration 0.5 to 199.9 m/s^2 magnetic base
range 0.05 to 20.39 g Dimension Meter :
2 to 656 ft/s^2 46.8 x 75.5 x 188 mm
Displacement 0.005 to 1.999 mm ( 1.8 x 3.0 x 7.4 inch ).
( p-p ) 0.002 to 0.078 inch Vibration sensor probe:
* p-p : Peak to Peak Round 18 mm Dia. x 40 mm.
Frequency 10 Hz to 1 KHz Accessories Instruction manual.................................. 1 PC.
range * Sensitivity relative during the included Vibration sensor ( VB-82 )....................... 1 PC.
the frequency range meet ISO 2954 Magnetic base........................................ 1 PC.
Refer to table 1, page 28. Reflecting tape marks (600 mm)............ 1 PC.
Function Velocity RMS, Peak, Max. hold (peak). RPM cone rubber............................... 1 PC.
Acceleration RMS, Peak, Max. hold (peak). RPM funnel rubber.............................. 1 PC.
Displacement p-p, Max. hold (p-p). Carrying Case......................................... 1 PC.
* Peak : To measure the peak value. Optional * Data Acquisition software,
* p-p : Peak to peak value. accessories .........................................SW-U801-WIN
* Max. hold : To hold the max. peak or p-p value. * Data Logger software, SW-DL2005
Accuracy ± ( 5 % + 2 d ) reading , 160 Hz, 80 Hz. * RS232 cable.................. UPCB-02
* 23 ± 5 ℃ * USB cable.................... USB-01
Data hold Freeze the desired reading.