Features:
- Quick Setup with On-Screen Guide: A step-by-step setup guide helps ensure you capture the right measurements
- Real-time remote monitoring on compatible PC and Android devices via Bluetooth communication
- Simultaneously measures power, harmonics, waveform, power quality (voltage: 3-channel, current: 4-channel)
- Full Analysis with Included Software: Quickly analyze your recorded data to identify potential issues with report generation and data visualization.
- Test parameters: voltage, current, active/reactive/apparent power, PF and frequency all on one screen
- Power quality events: Swell, Dip, Interruption, transients, Inrush current, and flicker
- Automatic recording with memory for up to 1,000 parameters at user defined intervals
- Comes complete with measurement accessories, PC software, and large carrying case
Features | DM-5 Power Quality Analyzer |
Wiring connection | 1P2W, 1P3W, 3P3W, 3P4W |
Measurements and parameters | Voltage, current, frequency, active power, reactive power, apparent power, active energy, reactive energy, apparent energy, power factor (cos ø), neutral current, demand, harmonics, quality (swell/dip/interruption, transients/overvoltage, inrush current, unbalance rate), capacitance calculation for PF correction unit, flicker |
Voltage (rms) | Range: 600.0 / 1000 V Accuracy: ±0.2% + 0.2%f.s.(sine wave, 40 Hz to 70 Hz) Allowable input: 1% to 120% of each range (rms). 200% of each range (peak) Display range: 0.15% to 130 % of each range Crest factor: 3 or less Sampling speed of voltage transient: 24 μs Input impedance: approx. 1.67 MΩ |
Current (rms) | Accuracy: ±0.2% + 0.2%f.s. + accuracy of flex current sensor (sine wave, 40 Hz to 70 Hz) Allowable input: 1% to 110% of each range (rms). 200% of each range (peak) Display range: 0.15% to 130 % of each range Crest factor: 3 or less Input impedance: approx. 100 kΩ |
Swell / dip / interruption | Range: same as Voltage (rms) Accuracy: ±1.0% of nominal voltage Threshold value: In percentage of nominal voltage value |
Power and energy | CT-53 flex current sensor (3-ch): max. 6000 kW CT-500 flex current sensor (1-ch): max. 1000 kW Active power accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 40 Hz to 70 Hz) Influence of power factor: ±1.0% (PF 0.5, 40 Hz to 70 Hz ) Wh: 0.00000 mWh to 9999.99 TWh VAh: 0.00000 VAh to 9999.99 TVAh varh: 0.00000 varh to 9999.99 Tvarh |
Power factor | Display range: -1.000 to 0.000 to 1.000 Accuracy: ±1dgt against each calculated value (for sum: ±3dgt) |
Harmonics | Harmonics order (n): 1 to 50th Inter-harmonics order (n): 1 to 50th Volts: 0.0% to 100.0%, accuracy (≥3% at 100 V nominal voltage): ±10% accuracy (<3% at 100 V nominal voltage): ±0.3% of nominal voltage accuracy (1000 V range): ±0.2% + 0.2%f.s Amps: 0.0% to 100.0%, accuracy (≥10% to max. input range): ±10% + flex current sensor accuracy (<10% to max. input range): ±1.0% + flex current sensor Watts: 0.0% to 100.0%, accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 50/60 Hz) THD: 0.0% to 100.0%, Phase angle: 0.0° to ± 180° |
Flicker | Displayed items: Pst(1min), Pst, Plt, Max Pst, Max Plt, V, time left Measurement method: Complied with IEC 61000-4-30 and IEC 61000-4-15 Ed.2 Accuracy: Pst (max.20): ±10% according to IEC 61000-4-15 |
Unbalance | Volts: 0.00% to 100.00%, accuracy: ±0.3% at 50/60 Hz, sine wave (0.00% to 5.00% according to IEC 61000-4-030) Current: 0.00% to 100.00% |
Transient | Approx. 40.96 ksps (every 2.4 μs) Range: 50 V to 2200 Vdc Accuracy: ±0.5% at 1000 Vdc |
Inrush current | Range: same as Current (rms) Accuracy: ±0.4% + 0.4%f.s. + accuracy of flex current sensor Threshold value: In percentage of the measurement range |
Capacitance | Range: 0.000 nF to 9999 F, 0.000 kvar to 999 kvar |
Specifications | |
Display | 3.5inch, TFT, QVGA(320xRGBx240) |
Display update | Every 1 second* *There may be time lag in display update (max. 2 seconds) due to arithmetic processing. However, no time lag between the recorded data and the time stamp |
Operating temperature and humidity | 32°F to 113 °F (0 °C to 40 °C), ≤ 85 %RH (no condensation) Guaranteed accuracy at 73 °F ± 9 °F (23 °C ± 5 °C), ≤ 85 %RH (no condensation) |
Operating altitude | 0 to 6,561 ft (0 to 2,000 m) |
Pollution degree | 2 |
Dust/water proof | IP 40 |
Drop proof | 3.3 ft (1 m) |
Storage temperature and humidity | -4 to 140 °F (-20 °C to 60 °C), ≤ 85 % RH (no condensation) |
Power supply | Battery: 6 x AA 1.5 V Alkaline battery (LR6) AC power supply: AC100 V to AC 240 V, 50 Hz to 60 Hz, 7 VAmax |
Battery life | 3 hours (typical) Current consumption: 1.0 A at 3.0 Vdc (typical) |
EMC | Meets EN 61326-1 |
Safety compliance | UL/IEC 61010-1, IEC 61010-031, IEC 61010-2-030 |
Power quality measurement | Complies with IEC 61000-4-030 ed.2 Class S |
Certification | |
Dimensions (L x W x D) | 6.9 x 4.7 x 2.7 in (17.5 X 12 X 6.8 cm) |
Weight | Approx. 2.0 lb (900 g) with batteries installed |